Show simple item record

dc.contributor.authorUgwu, Nicholas U.
dc.contributor.authorRanganai, Rubeni T.
dc.contributor.authorSimon, Rapelang E.
dc.contributor.authorOgubazghi, Ghebrebrhan
dc.date.accessioned2016-11-01T12:48:36Z
dc.date.available2016-11-01T12:48:36Z
dc.date.issued2016
dc.identifier.citationUgwu, N. U. et al. (2016) Geoelectric Evaluation of Groundwater Potential and Vulnerability of Overburden Aquifers at Onibu‐Eja Active Open Dumpsite, Osogbo, Southwestern Nigeria. Journal of Water Resource and Protection, Vol. 8, No. 3, pp. 311‐329en_US
dc.identifier.issn1945-3094 (Print)
dc.identifier.issn1945-3108 (Online)
dc.identifier.urihttp://hdl.handle.net/10311/1539
dc.descriptionThe symbols on the abstract may not appear as in the original article.en_US
dc.description.abstractElectrical resistivity method was used to assess groundwater potential and vulnerability of overburden aquifers at Onibu‐Eja active open dumpsite, Osogbo, Southwestern Nigeria. Eighteen Vertical Electrical Sounding (VES) points and five 2‐D imaging profiles established in five traverses at the periphery of the dumpsite were surveyed and analysed. The subsurface comprised of thin topsoil (resistivity 65 ‐ 998 Ωm); heterogeneous weathered layer with resistivity 63 ‐ 333 Ωm and thickness 0.7 ‐ 8.5 m; weathered basement (resistivity 31 ‐ 253 Ωm and thickness 0.7 ‐ 27.0 m) and fractured/fresh basement (resistivity 36 ‐ 6213 Ωm). The 2‐D inverse model of the profiles delineated low resistivity values ranging from 5 to 100 Ωm at a depth range of 10 ‐ 20 m along traverses TR1‐TR3 which is attributed to leachate percolation close to the dumpsite. The weathered basement was inclined relative to the dumpsite. The total overburden thickness varies from 6.9 to 33.7 m, with 20 and 40 m generally recommended as productive for groundwater abstraction in Southwestern Nigeria occurring in 61% of the area. Further, about 85% of the weathered layer resistivity values fall within medium groundwater potential (100 ‐ 250 Ωm) and high groundwater potential (>250 Ωm). The ranking of groundwater potential as a function of saprolite (weathered basement) resistivity showed that 72% of the study area is characterized by optimum weathering (20 - 100 Ωm) and is classified as good groundwater potential. Fractured basement covered <30% of the study area. The evaluation of aquifer protective capacity has helped to classify the area into moderate, weak and poor protective capacities with moderate protective capacity zone covering 72%.en_US
dc.language.isoenen_US
dc.publisherScientific Research Publishing Inc., http://www.scirp.org/journal/JWARP/en_US
dc.subjectSouthwestern Nigeriaen_US
dc.subjectcrystalline rocksen_US
dc.subjectelectrical resistivityen_US
dc.subjectgroundwater potentialen_US
dc.subjectvulnerability mappingen_US
dc.titleGeoelectric Evaluation of Groundwater Potential and Vulnerability of Overburden Aquifers at Onibu-Eja Active Open Dumpsite, Osogbo, Southwestern Nigeriaen_US
dc.typePublished Articleen_US
dc.linkhttp://www.scirp.org/journal/PaperInformation.aspx?paperID=64880en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record